Part Number Hot Search : 
00144 35100 B3868 SY89231U SSF5BG DM106 2N956 T352A
Product Description
Full Text Search
 

To Download AG8000 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 V1.3 July 2006 Data Sheet
Silver
TELECOM
Pb
AG8000
Power-Over-Ethernet Module 1. Features
IEEE802.3af compliant Small package size - 56mm (L) x 14mm (H) Low output ripple and noise Input voltage range 36V to 60V Only one low cost external decoupling capacitor required Overload and short-circuit protection Adjustable Output - 3 product variants cover all voltages from 2.4V to 13V Thermal Cut Off High efficiency DC/DC converter Silver Telecom "design-in" assistance
2. Description
The AG8000 series of modules are designed to extract power from a conventional twisted pair Category 5 Ethernet cable, conforming to the IEEE 802.3af Power-over-Ethernet (PoE) standard. IEEE 802.3af allows for two power options for Category 5 cables and the AG8000 series have two pairs of power inputs pins: - VA1&2 and VB1&2 to accommodate this, see Figure 1. The AG8000 signature and control circuit provides the PoE compatibility signature and power classification required by the Power Sourcing Equipment (PSE) before applying up to 15W power to the port. The AG8000 is compatible with Class 0 to Class 3 equipment. The high efficiency DC/DC converter operates over a wide input voltage range and provides a non-isolated regulated low ripple and low noise output. The DC/DC converter also has built-in output overload, output short-circuit and over-temperature protection.
(c) Silver Telecom 2006
V1.3 July 2006 Data Sheet
AG8000
Power-Over-Ethernet Module
Table of Contents
1. Features...........................................................................................................................1 2. Description.......................................................................................................................1 Table of Contents.............................................................................................................2 Table of Figures ...............................................................................................................2 3. AG8000 Product Selector .................................................................................................3 4. Pin Description.................................................................................................................4 5. Functional Description .....................................................................................................5 5.1. Inputs ........................................................................................................................5 5.2. PD Signature.............................................................................................................5 5.3. Isolation.....................................................................................................................5 5.4. Power Classification ..................................................................................................6 5.5. DC/DC Converter ......................................................................................................6 5.6. Grounding .................................................................................................................7 5.7. Output Adjustment.....................................................................................................7 5.8. Typical Connections ..................................................................................................8 6. Typical Application ...........................................................................................................9 7. Typical Recommendations.............................................................................................10 8. Operating Temperature Range ......................................................................................10 9. Electrical Characteristics................................................................................................13 9.1. Absolute Maximum Ratings* ...................................................................................13 9.2. Recommended Operating Conditions .....................................................................13 9.3. DC Electrical Characteristics* .................................................................................13 10. Package.......................................................................................................................14 10.1. AG8000-S ..............................................................................................................14 10.2. AG8000-D ..............................................................................................................14
Table of Figures
Figure 1: Block Diagram ......................................................................................................3 Figure 2: AG8000-S SIL Package Format ............................................................................3 Figure 3: Typical System Diagram.......................................................................................5 Figure 4: Class Programming Option...................................................................................6 Figure 5: Output Adjustment ................................................................................................7 Figure 6: Typical Connection Diagram.................................................................................8 Figure 7: Typical Application................................................................................................9 Figure 8: Typical Layout.....................................................................................................10 Figure 9: Power Plane Heatsink for AG8000 (-S or -D) ......................................................11 Figure 10: Ag8003 Operating Profile .................................................................................11 Figure 11: Ag8005 Operating Profile .................................................................................12 Figure 12: Ag8012 Operating Profile .................................................................................12
(c) Silver Telecom 2006
2
V1.3 July 2006 Data Sheet
AG8000
Power-Over-Ethernet Module
3. AG8000 Product Selector
Part Number Ag8012-S Ag8005-S Ag8003-S Ag8012-D Ag8005-D Ag8003-D Nominal Output Voltage 12.0V 5.0V 3.3V 12.0V 5.0V 3.3V Maximum Output Power * 12 6 5 12 6 5 Marking 12 5 3 12 5 3 Package SIL SIL SIL DIL DIL DIL
*At 25C with VIN = 48V All versions of the AG8000 are RoHS compliant.
Table 1: Ordering Information
VA1 Input VA2 VB1 Input VB2
AG8000
Signature & Control
DC:DC
Converter
DC Output
Figure 1: Block Diagram
AG8000-S 1
Figure 2: AG8000-S SIL Package Format
(c) Silver Telecom 2006
3
V1.3 July 2006 Data Sheet
AG8000
Power-Over-Ethernet Module
4. Pin Description
Pin # 1 2 3 4 5 6 7 8 9 10 Name VA1 VA2 VB1 VB2 CP1 CP2 -VDC +VDC ADJ IC Description RX Input (1). This input pin is used in conjunction with VA2 and connects to the centre tap of the transformer connected to pins 1 & 2 of the RJ45 connector (RX) - it is not polarity sensitive. TX Input (2). This input pin is used in conjunction with VA1 and connects to the centre tap of the transformer connected to pins 3 & 6 of the RJ45 connector (TX) - it is not polarity sensitive. Direct Input (1). This input pin is used in conjunction with VB2 and connects to pin 4 & 5 of the RJ45 connector. Direct Input (2). This input pin is used in conjunction with VB1 and connects to pin 7 & 8 of the RJ45 connector. Class Programming (1). Connect an external resistor to CP2 will change the current class of the module. With no resistor fitted the AG8000 will default to Class 0. Class Programming (2). Connect an external resistor to CP1 will change the current class of the module. With no resistor fitted the AG8000 will default to Class 0. Negative DC Output. This pin provides the regulated output from the DC/DC converter. Positive DC Output. This pin provides the regulated output from the DC/DC converter. Output Adjust. The output voltage can be adjusted from is nominal value, by connecting an external resistor from this pin to either the +VDC pin or the -VDC pin. Internal Connection. Do not connect to this pin.
(c) Silver Telecom 2006
4
V1.3 July 2006 Data Sheet
AG8000
Power-Over-Ethernet Module
5. Functional Description
5.1. Inputs
The AG8000 has two internal bridge rectifiers (see Figure 1: Block Diagram) connected to the VA1-VA2 and the VB1-VB2 inputs. This allows the AG8000 to be compatible with equipment that use the different power options, see Figure 3: Typical System Diagram. It is important that the PSE does not apply power to the VA and VB outputs at the same time (Refer to IEEE802.3af for more information).
POWER SOURCING EQUIPMENT (PSE) 4 4 POWERED DEVICE (PD)
+
5 5
+/1 TX 2 2 1 RX * * VA1 VB1 DC OUTPUT
PSE (48V)
RX
AG8000
3 3 TX 6 6
VA2 VB2 * *
+/7 7
8 8
* The VA and VB inputs must not be used at the same time
Figure 3: Typical System Diagram
5.2. PD Signature
When the AG8000 is connected to the Cat 5e cable, it will automatically present a Powered Device (PD) signature to the Power Sourcing Equipment (PSE) or Midspan Equipment, when requested. The equipment will then recognise that a powered device is connected to that line and supply power.
5.3. Isolation
The AG8000 series conforms to the IEEE 802.3af standard except for the 1500V isolation, which must be done externally. This is usually achieved without additional components, contact Silver Telecom for further details.
(c) Silver Telecom 2006
5
V1.3 July 2006 Data Sheet
AG8000
Power-Over-Ethernet Module
5.4. Power Classification
This is optional from the PSE and is used for power management. The AG8000 allows the current class to be externally programmed by connecting a resistor between the CP1 and CP2 pins, see Figure 4: Class Programming Option. If no resistor is fitted the AG8000 will default to Class 0, a full list of programming resistor values are shown in Table 2: Class Programming. Programming Resistance (Ohms) Do not fit 698 383 243 TBD Min Power (W) 0.44 0.44 3.84 6.49 Reserved Max Power (W) 12.95 3.84 6.49 12.95 Reserved
CLASS 0 1 2 3 4
Table 2: Class Programming
AG8000
CP1 R CP2
Class Programming option
Figure 4: Class Programming Option
5.5. DC/DC Converter
The AG8000's DC/DC converter provides a non-isolated regulated low ripple and low noise output, that has built-in overload and short-circuit output protection, as well a built-in thermal cut-off - see Table 1: Ordering Information for voltage and power ratings. Because the AG8000 series is non-isolated the +VDC output is connected to the positive input through a diode bridge.
(c) Silver Telecom 2006
6
V1.3 July 2006 Data Sheet
AG8000
Power-Over-Ethernet Module
5.6. Grounding
If the AG8000 is supplied from a grounded source (e.g. a standard multi-channel PSE) it is important that the -VDC output is NOT connected to ground. Connecting both input and output to ground will short circuit the input diode bridge, this prevents correct operation of the AG8000.
5.7. Output Adjustment
The AG8000 has an ADJ pin, which allows the output voltage to be increased or decreased from its nominal value. Figure 5: Output Adjustment shows how the ADJ pin is connected: -
AG8000
+VDC R ADJ
AG8000
+VDC
ADJ R
-VDC
-VDC
Increasing the output voltage from nominal
Reducing the output voltage from nominal
Figure 5: Output Adjustment Reducing the output voltage, connect R between ADJ and -VDC Value of R Ag8003 output Ag8005 output Ag8012 output Open Circuit 3.3V 5.0V 12.0V 15K 3.0V 4.3V 9.0V 0 Ohms 2.5V 2.5V 7.5V Increasing the output voltage, connect R between ADJ and +VDC Value of R Ag8003 output Ag8005 output Ag8012 output Open Circuit 3.3V 5.0V 12.0V 15K 3.5V 5.3V 12.5V 0 Ohms 4.5V 7.5V 13.0V Table 3: Output Adjustment Resistor (R) Value
*Note: the results in Table 3 are under minimum load conditions
(c) Silver Telecom 2006
7
V1.3 July 2006 Data Sheet
AG8000
Power-Over-Ethernet Module
5.8. Typical Connections
The AG8000 only requires one external component as shown in Figure 6: Typical Connection Diagram, a minimum of 470F is recommended. The value of C1 will be related to the maximum load step change that the output needs to drive. For example, in an application were the output needs to cope with a 1.8 Amp load step change, a minimum of 1000F should be used. This can be a standard low cost electrolytic and does not need to be a low ESR type. Figure 6 shows a 16V capacitor that would cover all product variants up to and including the Ag8012, see Table 1: Ordering Information. The Class programming and the Output Adjust inputs are optional and are provided to give great flexibility to the AG8000 product range. Further information on using these inputs can be found in sections 5.4. Power Classification and 5.7. Output Adjustment.
RJ-45 4 VB1 5 7
AG8000
VB2 ADJ
8 VA1 1 RX 2 VA2 3 TX 6 CP1 -VDC +VDC + Output C1 470F 16V
CP2
Figure 6: Typical Connection Diagram
(c) Silver Telecom 2006
8
V1.3 July 2006 Data Sheet
AG8000
Power-Over-Ethernet Module
6. Typical Application
The AG8000 can be used in numerous applications. In the example shown in Figure 7: Typical Application, the data outputs from the switch are connected to the inputs of a midspan. The midspan will then add power (to the data) on each output that supports Power over Ethernet (PoE). In this example port 1 is connected to an ethernet camera and port 2 is connected to a wireless access point, both of these devices have a built-in AG8000. When the midspan is switched on (or when the device is connected), the midspan will check each output for a PoE signature. On ports 1 and 2 the AG8000 will identify themselves as PoE enabled devices and the midspan will supply both data and power to these peripherals. The other ports (shown in this example) will not have a PoE signature and the midspan will only pass the data through to these peripherals. The midspan will continuously monitor each output to see if a PoE enabled device has been added or removed.
8
1
Switch
Patch Cables 8 1 Midspan Equipment
Ethernet Camera
AG8000
AG8000-S
Wireless Access Point
PC's and other non PoE peripherals
Figure 7: Typical Application
(c) Silver Telecom 2006
9
V1.3 July 2006 Data Sheet
AG8000
Power-Over-Ethernet Module
7. Typical Recommendations
Figure 8: Typical Layout gives an example of the tracking needed for the AG8000. R1, R2 and R3 are optional components, but C1 needs to be positioned close to the output pins of the AG8000 as possible to minimise the current loop. The thermal performance of the AG8000 can be improved by increasing the surface area of the output tracks (+VDC and VDC) this is not applicable if the AG8000 is in a socket.
CLASS R1
ADJ R2 R3 _ +
1 VA & VB Inputs
AG8000-S
* * Output C1 Voltage
* Heat dissipation of the AG8000 can be improved by increasing the surface area of the +VDC and GND output tracks.
Figure 8: Typical Layout
8. Operating Temperature Range
Because the AG8000 is a power component, it will generate heat, so it is important that this be taken into consideration at the design stage. The heart of the AG8000 is a DC/DC converter, which like any other power supply will generate heat. The amount of heat generated by the module will depend on the load it is required to drive and the input voltage supplied by the PSE. The information shown within this section of datasheet is referenced to a nominal 48Vdc input voltage supplied by the PSE. The AG8000 has a maximum ambient operating temperature of 70 OC see Figure 10, Figure 11 & Figure 12. These results are in still air without any heatsinking, the performance of the AG8000 can be improved by forcing the airflow over the part or by using a heatsink (see the AG8000 application note on heatsinking for more information). The output stage of the AG8000 has a built-in thermal protection circuit, to prevent the module from being damaged if operated beyond its power / temperature specification. Because each application is different it is impossible to give fixed and absolute thermal recommendations. However it is important that any enclosure used has sufficient ventilation for the AG8000 and a direct airflow if possible.
(c) Silver Telecom 2006
10
V1.3 July 2006 Data Sheet
AG8000
Power-Over-Ethernet Module
One simple method for drawing some of the heat away from the AG8000 is shown in Figure 9. Power planes connected to the +VDC and GND pins of the AG8000 can be used to draw heat away from the DC/DC converter via the output pins. These power planes must be on the outer layers of the PCB and the AG8000 must not be fitted into a socket (this example is suitable for both -S and -D variants).
Power Plane ADJ R2 R3 _ +
1 VA & VB R1 Inputs CLASS
AG8000-S
Output Voltage
Figure 9: Power Plane Heatsink for AG8000 (-S or -D) Figure 10, Figure 11 & Figure 12 show the maximum ambient temperature under different load conditions. These figure have been recorded in a sealed enclosure (in still air) using a heater element to elevate the ambient temperature (within the enclosure).
5 4 Output Power (W) 3 2 1
-20
-10
0
10
20
30
40
50
60
70
Ambient Temperaure (C)
Figure 10: Ag8003 Operating Profile (c) Silver Telecom 2006
11
V1.3 July 2006 Data Sheet
AG8000
Power-Over-Ethernet Module
6 5 4 Output Power (W) 3 2 1
-20
-10
0
10
20
30
40
50
60
70
Ambient Temperaure (C)
Figure 11: Ag8005 Operating Profile
12 11 10 Output Power (W) 9 8 7 6 5 4 3 2 1
-20
-10
0
10
20
30
40
50
60
70
Ambient Temperaure (C)
Figure 12: Ag8012 Operating Profile
(c) Silver Telecom 2006
12
V1.3 July 2006 Data Sheet
AG8000
Power-Over-Ethernet Module
9. Electrical Characteristics
9.1. Absolute Maximum Ratings*
Parameter 1 2 3 DC Supply Voltage DC Supply Voltage Surge for 1ms Storage Temperature Symbol VCC VSURGE TS Min -0.3 -0.6 -40 Max 60 80 +100 Units V V
O
C
*Exceeding the above ratings may cause permanent damage to the product. Functional operation under these conditions is not implied. Maximum ratings assume free airflow.
9.2. Recommended Operating Conditions
Parameter 1 2 3 Input Supply Voltage Under Voltage Lockout Operating Temperature Symbol VIN VLOCK TOP Min 36 30 -20 25 Typ 48 Max 60 36 70 Units V V Ta / OC
See Section 8. Operating Temperature Range
9.3. DC Electrical Characteristics*
DC Characteristic 1 2 3 4 5 6 7 8 9 10 Output Voltage Output Current (VIN = 48V) Line Regulation Load Regulation Output Ripple Output Ripple and Spikes Minimum Load Short-Circuit Duration Efficiency Temperature Coefficient Sym VOUT IOUT VLINE VLOAD VRP VSPK RLOAD TSC EFF TC 74 0.05 100 0.1 3.5 100 200 Min 2.5 2.5 7.5 Typ* 3.3 5 12 Max 4.5 7.5 13 1.5 1.2 1 Units V V V A A A % % mVp-p mVp-p mA sec % % @ Max load @ Max load for specified regulation Continuous @ 50 OC, VIN=48V Ag8012 @ 50% Load Per OC Test Comments Ag8003 Ag8005 Ag8012 Ag8003 Ag8005 Ag8012
*Typical figures are at 25C with a nominal 48V supply and are for design aid only. Not Guaranteed The output ripple and spikes can be reduced with an external filter, see application note. Can be used with no load at reduced voltage regulation.
(c) Silver Telecom 2006
13
V1.3 July 2006 Data Sheet
AG8000
Power-Over-Ethernet Module
10. Package
10.1. AG8000-S
10.0 (max) 56.0
14.0
AG8000-S 1
3.0 0.6 0.05
7.0 (max)
1.8 0.25 2.54 0.05
30.48 0.25
0.6 0.05
(Recommended PCB hole diameter = 1.1 0.05) Dimensions (in mm) are nominal unless otherwise stated
10.2. AG8000-D
11.0 (max) 56.0
14.0
0.6 0.05
AG8000-D 1
3.0
1.8 0.25 2.54 0.05
30.48 0.25
(Recommended PCB hole diameter = 1.1 0.05) Dimensions (in mm) are nominal unless otherwise stated
(c) Silver Telecom 2006
14


▲Up To Search▲   

 
Price & Availability of AG8000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X